Liming Heavy Industry
English | Español
 Rock Crusher Series
 Sand Making Series
 Grinder Series
Please feel free to give your inquiry in the form below. We will reply you with details ASAP.
Message:

Spinal Cord Impactor

Osteopontin-Deficient Mice Exhibit Less Inflammation, Greater …

We modified an impactor used to produce rat spinal cord contusion injury (Beattie et al., 1997) to produce a suitable injury in mice.

Transplantation of mononuclear cells from human umbilical …

Spinal cord injury rats had 25% loss of cord … Cell therapy; Functional recovery; Mononuclear cells; Human umbilical cord blood; MASCIS impactor …

A Cost Analysis of Spinal Cord Injury Research

Many people are raising funds for spinal cord injury (SCI) … First, we provide and train people to use the IMPACTOR model of rat spinal cord contusion.

Clinics – Spinal cord regeneration: the action of …

NEW YORK UNIVERSITY, Medical Center. Impactor. NYU Spinal cord contusion system. Operation manual. Impactor software version 7.0. New York, …

Spinal Cord Injury: Progress, Promise, and Priorities

Spinal Cord Injury examines the future directions for research with the goal to accelerate the … impactor, the Infinite Horizons device, and the Multicenter …

China Spinal Cord Injury Network (ChinaSCINet) – ChinaSCINet …

The ChinaSCINet is the largest spinal cord injury clinical trial network in … and provided the Impactor to over 500 laboratories around the world to do spinal …

ScienceDirect.com – Experimental Neurology – Spinal cord …

In spinal cord injury (SCI), … (UPH), and the other with the impactor positioned more medially, yielding larger, bilateral primary hemorrhages (BPH) …

Spinal Cord Injury: Impact of Functional Rehabilitation on …

A. Curt, MD Spinal Cord Injury Center, University of Zuerich ICORD, University of British Columbia Spinal Cord Injury: Impact of Functional Rehabilitation on

ScienceDirect.com – The Spine Journal – Ivan Cheng, Robert E …

Moderate spinal cord contusion was induced by the Multicenter Animal Spinal Cord Injury Study Impactor with 10-g weight dropped from a height of 25 mm. Experimental …

PLOS ONE: Spatio-Temporal Progression of Grey and White …

Spinal impactor device and measurements of initial injury volume. … the depth of penetration of the impactor tip into the spinal cord, (d) …

Reparixin, an Inhibitor of CXCR2 Function, Attenuates …

Spinal Cord Injury with UTS Impactor and Drug Treatment. The traumatic SCI was performed by means of the UTS impactor. The UTS impactor consists of a small impacting …

PinPoint™ Precision Cortical Impactor™|Hatteras Instruments

PinPoint™ is a Precision Cortical Impactor™ used in basic medical research to replicate traumatic brain and spinal cord injuries in an animal …

Spinal Cord – Effect of postinjury intravenous or intrathecal …

Spinal Cord is the official journal of the International … The impactor and the weight were immediately removed from the injured spinal cord and the cord …

Migration of Mesenchymal Stem Cells Through Cerebrospinal Fl …

mesenchymal stem cells, green fluorescent protein, spinal cord injury, NYU Impactor, cell transplantation, cell differentiation. Search for Similar Articles

PLOS ONE: Biomarkers for Severity of Spinal Cord Injury in …

To find biomarkers of SCI severity we used a standardized rat injury model in which an electro-mechanic impactor strikes the spinal cord and displaces it to a …

Basic Science Lab

NYU spinal cord injury impactor device. Two Forma water-jacketed incubators. Two isolated Sterileguard hoods (Baker Co. Inc.). Thermo IEC Centra-CLR3 centrifuge.

Characterization of Graded Multicenter Animal Spinal Cord In …

contusion, spinal cord injury, NYU-MASCIS impactor, somatosensory-evoked potential (SEP), BBB locomotor scale, rat. Search for Similar Articles

BMP inhibition enhances axonal growth and functional recovery …

We contused the spinal cords by using the Infinite Horizon Spinal Cord Impactor (Precision Systems and Instrumentation, Lexington, KY, USA).

Protective effects of oral creatine supplementation on spinal …

Impact velocity and compression depth were recorded and analyzed (NYU spinal cord contusion system, Impactor software version 7.0) as described previously. 30,31.

New Jersey Commission on Spinal Cord Research

Our group developed the Impactor model of rat spinal cord injury, and helped develop the BBB scale, a widely used behavioral score of locomotor recovery.

Spinal cord injury – IEEE Conferences, Publications, and …

New Robo-cylinder Impactor System for the Spinal Cord Injury Model. Jeong-Kyu Yang; Chul Ung Kang; Jong Hwan Lim; Tae Kyun Shin; …

Transplantation of embryonic stem cell-derived neural stem …

spinal cord injury (SCI) in mice and whether a combination treatment with thyroid hormone … pneumatic impactor (INP-150; Scholar Tec, Osaka, Japan) …

Core B – Surgery & Animal Care — University of Louisville

Kentucky Spinal Cord Injury Research Center. About. Researchers. Patients & Caregivers. Physicians & Referrals. Support Our Research. … LISA and NYU impactor devices;

The Journal of stone & Joint Surgery | Article

Transplantation of Preconditioned Schwann Cells in Peripheral Nerve Grafts After Contusion in the Adult Spinal Cord: … a force-directed impactor in forty …

Motor recovery following olfactory ensheathing cell …

Figure 1: Graph shows the trajectory of the rod in the spinal cord impactor, when it is dropped and retracted to make a drop weight injury to the rat spinal cord.

BMC Neuroscience | Abstract | The effect of mesenchymal stem …

Neurogenic bladder following spinal cord injury is the main problem decreasing the … spinal cord of Sprague-Dawley rats using MASCIS impactor and …

Advocacy Webinars Strengthen Efforts to Impact Disability …

NSCIA’s free webinar series empowers advocates to address concerns of disability community at “Roll on Capitol Hill” in Washington, DC this June.

BMC Neuroscience | Full text | The effect of mesenchymal stem …

Using a Multicenter Animal Spinal Cord Injury Study (MASCIS) impactor (Rutgers, the State University of New Jersey, Newark, NJ), a 10 …

MIRM, Bangalore – Manipal University – one of the top most …

48 IH-0400 Mouse/Rat spinal cord impactor Precision System and Instrumentation IH Impactor 49 Microscope Light,Laboratory,sterio Nikon Corporation, Japan SMZ 1500-

Wise Young – Welcome | Division of Life Sciences, Rutgers …

We study a variety of therapies in the well-standardized IMPACTOR model of rat spinal cord … progressive damage in the brain and spinal cord, …

Sitemap  |  Clients Cases  |  Service  |  Honour  |  Contact Us
Copyright © Liming Heavy Industry. All rights reserved   E-mail: [email protected]